Brand Name : Shenglin
Model Number : SHSL-D3 Series
Certification : CE and Rohs
Place of Origin : China
MOQ : 1
Price : 600~32000 USD per unit
Payment Terms : T/T, Western Union
Supply Ability : 100 units per month
Delivery Time : 35~40days
Packaging Details : Stretch film and Pallet
Tube material : Copper tubes
Fin material : Hydrophilic aluminum foil or epoxy resin aluminum foil
Frame material : Galvanized steel plate or stainless steel
Power supply : 380V/3P/50Hz or 380V/3P/60Hz
Fan brand : Ziehl-Abegg
Frame painting colour : White
Product category : Dry Cooler
Cooling way : Immersed Cooling
Structure : Table or V type
Media : Electrocool dielectric coolants
Two-phase Immersed Cooling System For Datacenters
What's ImmersedCooling?
Immersion cooling is an IT cooling practice by which IT components and other electronics, including complete servers, are submerged in a thermally conductive dielectric liquid or coolant. Heat is removed from the system by circulating liquid into direct contact with hot components, then through cool heat exchangers. Fluids suitable for immersion cooling have very good insulating properties to ensure that they can safely come into contact with energized electronic components.
Benefits of Immersed Cooling:
Reduce Operating Costs by 50%+
Power reduction by removing the fans from the miners (~18% – 25%)
Removal of supplementary cooling systems (Intake / Exhaust fans, etc. account for another 20% – 25%)
Increase the hash rate of your current equipment
Increase hardware lifespan
Increase the density of miners in your facility
Built in fire protection as our dielectric fluid is non-flammable
Immersion cooling systems do not require chillers, CRAC units, raised flooring, etc
Many more!
With our Immersed Cooling System, servers are immersed in closed containers in a non-toxic, non-conductive liquid and the heat is dissipated quickly and effectively, resulting in a cooling capacity of more than 2000X that of air cooling.As a result, electricity consumption decreases by 90%, and the performance of the servers increases by 250%.
Our proprietary solution enables customers to host their service in a fully controllable environment. Two-phase cooling allows for a much higher density than standard air cooling, and consumes much less space, allowing datacenters to become more efficient, reduce their power consumption by 60% and increase density.
Technical parameter of dry cooler
Dry cooler D3 series parameter(fin space 2.1mm)
Type | D3-042- 1X800 | D3-046- 1X800 | D3-051- 1X800 | D3-087- 2X800 | D3-094- 2X800 | D3-103- 2X800 | D3-125- 3X800 | D3-146- 3X800 | D3-153- 3X800 | D3-175- 4X800 | D3-188- 4X800 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | KW | 42.1 | 46.1 | 50.6 | 87.3 | 93.6 | 102.9 | 124.9 | 145.9 | 153.3 | 174.5 | 187.9 | |
outlet | 40℃ | ||||||||||||||||
20% Glycol | Inlet | 45℃ | 40.8 | 45.1 | 49.7 | 84.5 | 91.8 | 100.9 | 119.4 | 143 | 150.4 | 168.9 | 184.3 | ||||
outlet | 40℃ | ||||||||||||||||
Medium | Water flow | M3/h | 7.3 | 8 | 8.8 | 15.2 | 16.3 | 17.9 | 21.7 | 25.4 | 26.6 | 30.3 | 32.7 | ||||
Pressure drop | kPa | 49 | 69 | 97 | 48 | 98 | 93 | 21 | 97 | 89 | 48 | 98 | |||||
Air flow | M3/h | 21454 | 20531 | 19696 | 42906 | 41061 | 39390 | 64364 | 61585 | 59087 | 85811 | 82120 | |||||
Fan motor(400V/3N/50HZ) | W | 1800 | 1800 | 1800 | 3600 | 3600 | 3600 | 5400 | 5400 | 5400 | 7200 | 7200 | |||||
A | 3.8 | 3.8 | 3.8 | 7.6 | 7.6 | 7.6 | 11.4 | 11.4 | 11.4 | 15.2 | 15.2 | ||||||
Fan | No X φ | 1x1 x800 | 1x1 x800 | 1x1 x800 | 1x2 x800 | 1x2 x800 | 1x2 x800 | 1x3 x800 | 1x3 x800 | 1x3 x800 | 2x2 x800 | 2x2 x800 | |||||
Sound pressure level | dB(A) | 50 | 50 | 50 | 51 | 51 | 51 | 53 | 53 | 53 | 54 | 54 | |||||
10m | |||||||||||||||||
Dimension | L | mm | 2000 | 2000 | 2000 | 3800 | 3800 | 3800 | 5600 | 5600 | 5600 | 3800 | 3800 | ||||
W | mm | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 2108 | 2108 | 2108 | |||||
H | mm | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | |||||
A | mm | 1728 | 1728 | 1728 | 3528 | 3528 | 3528 | 5328 | 5328 | 5328 | 3528 | 3528 | |||||
B1 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
B2 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
B3 | mm | -- | -- | -- | -- | -- | -- | 1776 | 1776 | 1776 | -- | -- | |||||
B4 | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
X | mm | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 2021 | 2021 | |||||
Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
Product weight(empty) | kg | 225 | 233 | 241 | 357 | 373 | 392 | 796 | 527 | 749 | 812 | 1062 |
Some immersion cooling system dry cooler reference:
![]() | ![]() |
Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 1270kW Cooling medium: BC-888 Supply power: 415V/3P/60Hz Fan brand: Ziehl-Abegg
| Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 171kW Cooling medium: bitcoin fluid Supply power: 415V/3P/60Hz Fan brand: Chinese brand
|
![]() |