Flat Series Dielectric Coolants Datacenters Submerged Server Cooling Dry Coolers

Brand Name : Shenglin

Model Number : H*FS Series

Certification : CE and Rohs

Place of Origin : China

MOQ : 1

Price : 610~32000 USD per unit

Payment Terms : T/T, Western Union

Supply Ability : 100 units per month

Delivery Time : 35~40days

Packaging Details : Stretch film and Pallet

Tube material : Copper tubes

Fin material : Hydrophilic aluminum foil or epoxy resin aluminum foil

Frame material : Galvanized steel plate or stainless steel

Power supply : 380V/3P/50Hz or 380V/3P/60Hz

Fan brand : Ziehl-Abegg

Frame painting colour : White or gray

Product category : Dry Cooler

Cooling way : Immersed Cooling

Structure : Table type

Media : Electrocool dielectric coolants

Contact Now

Flat Series Dielectric Coolants Datacenters Submerged Server Cooling Dry Coolers​

What's ImmersedCooling?

Immersion cooling is an IT cooling practice by which IT components and other electronics, including complete servers, are submerged in a thermally conductive dielectric liquid or coolant. Heat is removed from the system by circulating liquid into direct contact with hot components, then through cool heat exchangers. Fluids suitable for immersion cooling have very good insulating properties to ensure that they can safely come into contact with energized electronic components.

Benefits of Immersed Cooling:

Reduce Operating Costs by 50%+

Power reduction by removing the fans from the miners (~18% – 25%)

Removal of supplementary cooling systems (Intake / Exhaust fans, etc. account for another 20% – 25%)

Increase the hash rate of your current equipment

Increase hardware lifespan

Increase the density of miners in your facility

Built in fire protection as our dielectric fluid is non-flammable

Immersion cooling systems do not require chillers, CRAC units, raised flooring, etc

Many more!

With our Immersed Cooling System, servers are immersed in closed containers in a non-toxic, non-conductive liquid and the heat is dissipated quickly and effectively, resulting in a cooling capacity of more than 2000X that of air cooling.As a result, electricity consumption decreases by 90%, and the performance of the servers increases by 250%.

Our proprietary solution enables customers to host their service in a fully controllable environment. Two-phase cooling allows for a much higher density than standard air cooling, and consumes much less space, allowing datacenters to become more efficient, reduce their power consumption by 60% and increase density.

Two-phase liquid cooling:

The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃. In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat. The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid. The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.

Flat Series Dielectric Coolants Datacenters Submerged Server Cooling Dry Coolers

Some Reference:

  • For data center cooling or server liquid cooling:

Country: Mongolia

Application: match with precision air conditioner

Cooling capacity: 17.6kW

Cooling medium: 34% ethylene glycol

Supply power: 400V/3P/50Hz

Fan brand: Ziehl-Abegg

Country: Russia

Application:data center cooling

Cooling capacity: 763kW

Cooling medium: water

Supply power: 380V/3P/50Hz

Fan brand: Ziehl-Abegg

Flat Series Dielectric Coolants Datacenters Submerged Server Cooling Dry CoolersFlat Series Dielectric Coolants Datacenters Submerged Server Cooling Dry Coolers

Flat Series Dielectric Coolants Datacenters Submerged Server Cooling Dry Coolers

Flat Series Dielectric Coolants Datacenters Submerged Server Cooling Dry Coolers


Product Tags:

Datacenters submerged server cooling

      

dielectric coolants submerged server cooling

      

dielectric coolants submerged liquid cooling

      
Quality Flat Series Dielectric Coolants Datacenters Submerged Server Cooling Dry Coolers for sale

Flat Series Dielectric Coolants Datacenters Submerged Server Cooling Dry Coolers Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai Shenglin M&E Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0